Polyvinyl Chloride (PVC) is one of the most versatile and cost-effective thermoplastics in injection molding, available in rigid and flexible (plasticized) forms. It offers excellent chemical resistance, inherent flame retardancy from its chlorine content, and good electrical insulation at a very low material cost. Shinzoft delivers OEM/ODM PVC injection molding for fittings, electrical boxes, cable components, and medical connectors, from DFM through mass production.
Outstanding resistance to acids, alkalis, salts, alcohols, and many industrial chemicals. This is why PVC dominates pipe, fitting, and chemical-handling parts where other plastics corrode.
The chlorine in the molecule makes PVC self-extinguishing; it stops burning once the flame source is removed and does not drip. It meets strict fire-safety standards without added flame retardants.
High dielectric strength and good volume resistivity make rigid PVC a reliable insulator for conduit fittings, junction boxes, cable terminations, and switchgear.
PVC is among the cheapest engineering-grade thermoplastics. The same polymer base spans hard, structural parts and soft, rubber-like seals simply by changing the plasticizer level.
Values below refer to unfilled rigid PVC. Flexible compounds are softer and lower in modulus, with properties that shift according to plasticizer content.
| Property | Typical Value | Notes |
|---|---|---|
| Density | 1.35–1.45 g/cm³ | Rigid grades; flexible grades vary with plasticizer |
| Tensile Strength | 40–55 MPa | Rigid; flexible compounds drop to 10–25 MPa |
| Flexural Modulus | 2,400–3,000 MPa | Rigid; softens sharply as plasticizer is added |
| Heat Deflection Temp (HDT, 1.8 MPa) | 60–70 °C | Low for a rigid plastic; limits high-temperature use |
| Glass Transition Temp (Tg) | 75–85 °C | Amorphous polymer — no true melting point |
| Molding Shrinkage | 0.3–0.8 % | Low and predictable; flexible grades shrink slightly more |
| Dielectric Strength | 14–20 kV/mm | Good insulation for electrical housings and fittings |
| Parameter | Typical Range |
|---|---|
| Drying Temperature / Time | Usually not required; dry 70–80 °C / 1–2 h if stored damp |
| Melt Temperature | 180–210 °C (narrow, tightly controlled window) |
| Mold Temperature | 30–60 °C |
| Injection Pressure | 60–100 MPa |
| Typical Cycle Time | 20–50 s, depending on wall thickness |
Temperature control is the single most important variable in PVC molding. The processing window is narrow and close to its decomposition point: above roughly 210 °C the polymer begins shedding hydrogen chloride gas, which burns the melt, discolors the part, and attacks the screw and barrel. Hold barrel temperatures within grade limits, keep screw speed moderate to limit shear heating, shorten residence time, and vent the mold well so any trace gas escapes instead of scorching the surface. Heat stabilizers help but buy margin rather than immunity, so plan shutdowns rather than leave PVC hot in the barrel.
PVC's closest relatives in soft, flexible applications are the elastomers. Compared with TPE, flexible PVC is cheaper and inherently flame-retardant, but TPE has a cleaner rubber feel, better aging, and no plasticizer migration. Against TPU, PVC is far less abrasion- and oil-resistant, though it costs a fraction as much and needs no drying. Where chemical resistance, flame safety, and cost drive the decision, PVC stays practical.
Among rigid commodity plastics, PVC outruns ABS on chemical resistance and flame retardancy, but ABS is tougher and easier to process. PVC also beats most polyethylene grades on cost and flame behavior, though it gives up impact strength and a wide processing window. PVC buys chemical and fire resilience at the cost of careful process control.
Both use the same PVC base. Rigid PVC contains no plasticizer and behaves like a hard structural plastic with a tensile strength of 40–55 MPa, used for pipe fittings, valves, and electrical boxes. Flexible PVC is compounded with plasticizers that lower its modulus and make it soft and rubber-like, ideal for tubing, seals, and cable jackets.
PVC starts to decompose above roughly 210 °C and releases hydrogen chloride gas, which discolors the part, weakens it, and corrodes the tooling. The 180–210 °C window is narrow, so we hold barrel temperatures tightly, keep screw speed moderate, shorten residence time, and ensure the mold vents well.
Yes. PVC is inherently flame retardant because chlorine makes up a large part of its molecule. Exposed to flame it self-extinguishes once the source is removed and does not drip, so it meets fire-safety requirements without the additive flame-retardant packages other plastics require. This is a major reason PVC is used for electrical and construction parts.
Medical-grade flexible PVC is widely used for tubing, catheters, blood bags, and connectors. These grades use plasticizers and stabilizers selected for biocompatibility and meet USP Class VI and ISO 10993. We mold medical PVC only with certified compounds on dedicated, cleaned equipment.
PVC is not hygroscopic, so it generally does not require drying, unlike nylon or TPU. If the compound has been stored in a damp environment, a short dry of 1–2 hours at 70–80 °C removes surface moisture without risking the thermal degradation that prolonged high heat would cause.
Send your drawings and service conditions — chemical exposure, temperature, and fire-safety requirements. Our engineers will recommend the right rigid or flexible PVC compound and deliver consistent production.
Shinzoft serves customers worldwide with custom PVC injection molding solutions and a full range of injection molding materials.
Get a Free Quote →